Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | Daxian |
Model Number : | UL790 |
Price : | Negotiation |
Payment Terms : | L/C, T/T, D/A |
Supply Ability : | Five sets per month |
Applicable scope:
These requirements cover all roof materials exposed to simulated
fires outside the building, used for installation on combustible or
non combustible substrates. It is to evaluate the fire resistance
performance of the roof and components under simulated real
conditions, and to evaluate the AC level of the samples under
A1.82m, B 2.4m, and C 3.9m conditions. It can also be used for
flame retardant performance testing of photovoltaic cell modules.
Compliant with standards:
UL 1730: Smoke detectors for independent living units in multi
household residential and hotel/motel rooms. Monitor: Electric
signal to detect residential smoke and dust conditions;
UL 790: Standard test method for fire resistance testing of roof
coverings;
IEC 61730-2 Photovoltaic Module Appendix A Fire Test Flame
Propagation;
ASTM F 108-04: Standard test method for fire resistance testing of
roof coverings;
NFPA 256: Fire resistance testing of roof coverings;
Performance parameters:
Using cylinders to control the slope of the deck
Fireproof board with testing deck attached
Using automatic control valves to regulate temperature in stages
Plywood roof covering material, size 1300 (W)×1000 (D)×120 (H) for
installing test samples;
Non combustible testing board, installed at the end of the testing
board, can prevent the occurrence of tempering under the testing
board;
Stainless steel fan-shaped adjustment plate, adjustable testing
angle, size: 1440 (L) x 940 (H) mm;
Non combustible panel assembly, installed at the front end of the
frame, simulating eaves and eaves, extending flames from the burner
to the specimen, with dimensions of 330 (W) x 2130 (D) x 584 (H)
mm;
An independent exhaust duct that can extract air from outside the
laboratory;
A honeycomb filter is installed in the air duct, and guide vanes
are installed at the gas inlet;
A slope adjustment panel is installed on the ventilation duct to
adjust the direction of air flow;
There is a guide plate attached to the ventilation duct, which can
enhance the wind speed to ensure that the airflow supplied to the
test plate is not affected by external interference. The guide
plate is made of stainless steel and its position does not change
with wind pressure changes;
The air duct material is made of stainless steel, which is
corrosion-resistant and high-temperature resistant. The size is
2130 (W) x 762 (H) x 3000 (L) mm;
The fan is 220V, 50HZ, three-phase electric, equipped with a
reverse system that can automatically adjust the wind speed, with a
flow rate of 300m3/min;
Continuously variable speed reverse converter, adjustable from 0 to
100%;
Gas burner (used for intermittent ignition, flame propagation, and
flying fire tests), 1.12m long, with a diameter of 60.3mm, and a
narrow slit of 12.7mm (W) * 0.91m (L) on one side facing the test
plate;
The gas burner can provide 22000Btu/min (387kWh) and can
automatically adjust the gas flow rate according to three
combustion levels A, B, and C;
A thermocouple is installed at 58.7mm above the top of the burner,
which can test a temperature of 888±28℃;
Automatic ignition system, ensuring the safety performance of
testing, ignition electrode high voltage is 1.8kVp mass flow
controller;
Temperature automatic control system:
-Class A and B: 760±28℃ (1400±50℉) -21000~22000 Btu/min (369~387
kWh)
-Class C: 704±28℃(1300±50℉) -18000~19000 Btu/min (316~334 kWh).
Different testing and control methods must be followed for each gas
burner;
High precision pressure gauge and pressure regulating valve control
gas pressure:
-LNG: The use of MFM can accurately measure the gas flow rate (the
gas flow rate is controlled by an automatic control valve);
-LPG: Use inverter system to regulate air flow rate: Test the speed
on the deck to be 19 ± 8 km/h (5.5m/sec);
Metal mesh supports the material, and the tray can rotate to
facilitate full combustion of the material;
![]() |