Sign In | Join Free | My burrillandco.com
Home > Plastic Testing Equipment >

Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard

    Buy cheap Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard from wholesalers
     
    Buy cheap Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard from wholesalers
    • Buy cheap Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard from wholesalers
    • Buy cheap Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard from wholesalers
    • Buy cheap Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard from wholesalers

    Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard

    Ask Lasest Price
    Brand Name : DAXIAN
    Model Number : DX8388
    Certification : IEC 60243、ASTM D149
    Price : Negotiable
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
    Supply Ability : 30 sets per month
    Delivery Time : 30 days after order confirmed
    • Product Details
    • Company Profile

    Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard

    50KV IEC 60243-1 Dielectric Breakdown Voltage Test Equipment

    Application

    Apply to continuous uniform boosting or step by step boosting way, step by step toward a sample breakdown, ac/dc voltage until the breakdown voltage measurement, calculation of the sample breakdown strength.


    Definitions:

    Breakdown Voltage: Sample under a certain voltage is punctured, at this time of voltage named breakdown voltage, expressed as a kV.


    Voltage Resistance Value: Quickly to keep the voltage to the specified value, sample time is not breakdown, according to the voltage value of withstanding voltage value of the sample, expressed as a kV.


    Breakdown Strength: The ratio of the sample breakdown voltage and its thickness named breakdown strength, expressed a KV/mm.


    Specifications:

    Breakdown voltage0~50kV
    Booting speed100,200,500,1000,2000,5000(KV/S)
    Booting speed controlElectrical automatic control
    Voltage measurement accuracy≤ 2%
    The leakage current selection1~100 mA
    Methods of testDC & AC
    Methods of bootingAutomatic program-controlled
    Power Frequencysine wave 50Hz/60HZ
    Supply powerAC220V 50/60Hz
    DimensionL 1400* W 1040* H 1500 mm
    Weight200kg
    Transformer capacity10 KVA
    AC 0~50 KV (continuously adjustable)

    Quality Dielectric Breakdown Voltage Test Equipment 50KV IEC 60243-1 Standard for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)